23
GM 4700AC
B_02261
x
A
B
C
D
B_02384
OPERATING MANUAL
VERSION 09/2011
ORDER NUMBER DOC
2311730
For disassembly and assembly of AirCoat nozzles, see section 5.4.3.
AirCoat nozzle (C) can be placed into a cleaning solvent which has been recommended by
the paint manufacturer.
1.
Relieve the pressure of gun and unit.
2.
Secure gun with locking device.
3.
Unscrew the union nut with nozzle guard (A).
4.
Remove air cap (B).
5.
Push AirCoat nozzle (C) out of air cap (B) by hand, reverse it and put it towards the
rear onto nozzle seal (D).
6.
Refi t air cap (B) on nozzle (C). Take care with the fl attened parts (X) of the nozzle
and of the air cap.
7.
Fit the union nut with nozzle guard (A) over air cap (B) onto the spray gun and
tighten by hand.
8.
Switch the material pressure back on.
9.
Turn the locking device to the spraying position and briefl y pull trigger.
10.
When the blockage has been fl ushed out, secure the gun with the locking device.
11.
Relieve the pressure of gun and unit.
12.
Unscrew the union nut with nozzle guard (A).
13.
Remove air cap (B) and push AirCoat nozzle (C) out by hand. Clean the nozzle and
put it back on nozzle seal (D) in the spray position.
14.
Refi t air cap (B) on nozzle (C).
Take care with the fl attened parts (X) of the nozzle and of the air cap.
15.
Fit the union nut with nozzle guard (A) over air cap (B) onto the spray gun and
tighten by hand.
16.
Switch the material pressure and the air pressure back on.
Nozzle in „spray“ position
Nozzle in „cleaning“ position
5.4.4
CLEANING AIRCOAT NOZZLE
5.4.5
ELIMINATE NOZZLE CLOGGING