22
6.8
COMMISSIONING
NOTICE
Impurities in the spraying system!
Spray gun blockage.
Flush the spray gun and paint supply with a suitable flushing agent before
commissioning.
6.8.1 PROCEDURE
1. Secure the spray gun.
B_02261
x
2. Connect the product hose to the spray gun and product supply system.
3. Connect air hose to spray gun and to oil-free, dry air supply.
4. For spray guns with filters, insert a suitable filter (filter insert, see Chapter
5. Fit nozzle on nozzle seal. Fit air cap over nozzle.
Note the flattened parts (X) on the nozzle and in the air cap.
Fit the union nut with nozzle guard and tighten by hand.
6. Visually check the permissible pressures for all the system components.
7. Make sure that the device and all other conductive parts within the work area are
grounded.
8. Set operating pressure at 100 bar; 10 MPa; 1450 psi and use a suitable medium to
check that connections do not leak.
Note:
Pull the trigger and check whether the spray gun closes cleanly upon release.
9. Relieve the pressure of the spray gun and device and secure the spray gun.
6.8.2 VERIFYING A SAFE OPERATIONAL CONDITION
A skilled person must check to ensure that the device is in a reliable state after it is
installed and commissioned.
This includes:
– Carry out safety checks in accordance with Chapter
.
VERSION 06/2018
ORDER NUMBER DOC2311730
Summary of Contents for GM 4700AC
Page 1: ...AirCoat Manual Gun for Flat and Round Jet Nozzles Version 06 2018 B_02376...
Page 2: ......
Page 48: ...48...