12
GM 4700AC
OPERATING MANUAL
VERSION 06/2014
ORDER NUMBER DOC2311730
3
IDENTIFICATION
3.1
CE EXPLOSION PROTECTION IDENTIFICATION
As defi ned in the Directive 94/9/EC (ATEX), the device is suitable for use in potentially
explosive areas.
Device type:
AirCoat manual gun
Manufacturer:
J. Wagner AG
CH-9450 Altstätten, Switzerland
II 2G X
CE
European Communities
Ex
Symbol for explosion protection
II
Device class II
2
Category 2 (Zone 1)
G
Ex-atmosphere gas
X
Special Notice
3.2
IDENTIFICATION "X"
X: The maximum surface temperature corresponds to the permissible product
temperature.
This and the permissible ambient temperature can be found in the "Technical Data"
chapter.
Safe handling of WAGNER spray devices
Mechanical sparks can form if the device comes into contact with metal.
In an explosive atmosphere:
Do not knock or push the device against steel or rusty iron.
Do not drop the spray gun.
Only use tools that are made of a permitted material.
Ignition temperature of the coating product
Ensure that the ignition temperature of the coating product is above the maximum
surface temperature.
Medium supporting atomizing
To atomize the product, use only weakly oxidizing gases, e.g., air.
Cleaning
If there are deposits on the surfaces, the device may form electrostatic charges. Flames or
sparks can form during discharge.
Remove deposits from the surfaces to maintain conductivity.