31
8.2.5 CHANGING OR CLEANING FILTER INSERT
1. Flush and clean the spray gun in accordance
with Chapter
B_03649
64
83
66
67
open
2. Relieve the pressure of the spray gun and
device.
3. Secure the spray gun with the trigger
locking device.
4. Loosen the filter housing (67) manually with
turning handle (66) and unscrew it. When the
product hose together with filter housing
and filter insert has been exposed, push the
turning handle (66) back onto the upper filter
connection.
5. Pull the filter insert (64) out of the filter
housing (67).
6. Thoroughly clean all parts with flushing
agent.
Assembly:
7. Push the cleaned or new filter insert (64) with
opening downwards into the filter housing
(67).
8. Insert the filter housing (67) into the turning
handle, screw in manually with the turning
handle and tighten.
Procedure if connection is difficult to loosen:
Loosen filter housing (67) with wrench size
B open-end wrench, supporting the filter
connection with size A open-end wrench.
Wrench A
Wrench B
13 mm
0.51 inch
17 mm
0.67 inch
B_02387
B
A
Note:
Do not unscrew the
filter connection.
The filter connection
should be replaced
in accordance with
Chapter
.
VERSION 06/2018