37
B_03690
84
84
OPERATING MANUAL
EDITION 05/2015
ORDER NUMBER DOC2319150
GM 5000E gun cable
Extension cable to the
control unit
Attention: guns with electric extension cable
Secure the cover sleeves with the warning sign by means of the screws (84) on the
connectors.
Power loss
In order to prevent power losses, keep the cable length as short as possible. The maximum
power is available with the standard cable length of 10 m.
An extension to a total length of up to 40 m will cause a power loss of up to 10%. The gun
cable can be extended to a total length of 80 m, however, a power loss of up to 30% will
be caused.
A skilled person must check to ensure that the device and the spraying system are in a safe
state after they are installed and commissioned.
This includes:
- Carry out a safety check in accordance with Chapter 8.2.3.
- Function test in accordance with Chapter 11.
6.6.4
VERIFYING A SAFE OPERATIONAL CONDITION