45
GM 5000EA
OPERATING MANUAL
EDITION 04/2016
ORDER NUMBER DOC2344499
Discharge of electrostatically charged components in
atmospheres containing solvents!
Explosion hazard from electrostatic spark-over.
Use gun only with fi tted nozzle, air cap and union nut.
WARNING
7.2.2
GENERAL RULES FOR MAKING ADJUSTMENTS TO THE SPRAY GUN
High-voltage fi eld!
Danger to life from malfunction of heart pacemaker
Make sure that persons with pacemakers:
Do not work with the electrostatic spray gun.
Do not enter the high-voltage area.
DANGER
High-pressure spray jet!
Danger to life from injecting paint or solvent.
Never reach into the spray jet.
Never point the spray gun at people.
Consult a doctor immediately in the event of skin injuries caused
by paint or solvent. Inform the doctor about the paint or solvent
used.
Never seal defective high-pressure parts; instead relieve the pressure
from them and replace them immediately.
Wear the appropriate protective clothing, gloves, eyewear and
respiratory protection.
WARNING
In the case of unforeseen occurrences, proceed as follows:
1. Switch off control unit.
2. Close the compressed air supply.
3. Relieve pressure according to the operating manual of the product pressure
generator.
4. Point the spray gun toward the grounded collecting tray.
5. Pull the trigger of the spray gun until no further pressure is present.
7.2.1
EMERGENCY DEACTIVATION