26
GM 5000EAC
.
B_03234
R max < 1 M
Ω
OPERATING MANUAL
EDITION 03/2012
PART NUMBER DOC 2319150
Earthing schema (example)
Conveyor
Control unit
Earthing
cable
Spraying stand
Floor, derivable
Work piece
Pump
Paint container
Minimum cable cross-section
Control unit
4 mm² (AWG 12)
Pump
4 mm² (AWG 12)
Paint container
4 mm² (AWG 12)
Conveyor
16 mm² (AWG 6)
Booth
16 mm² (AWG 6)
Spraying stand
16 mm² (AWG 6)
Note for the sprayer
The work shoes and if
used the gloves must be
derivable.