Introduction
1.2 Technical
data
06_ .doc
Electrical:
Input voltage:
max. 22 Vpp
Input current:
max. 0.9 A
Frequency:
19 ... 30 kHz
Output voltage:
max. 100 kV DC
Polarity: negative
Design:
as per EN 50177
Protection class:
IP 54
Pneumatic:
Input air pressure (atomizing air):
max. 43.5 psi (3 bar)
Powder output quantity:
max. 450 g/min
06_ .doc
Required compressed air quality:
Quality class
Compressed air quality according to ISO 8573.1
5
Max. residual water:
(pressure dew point in °F at 100 psi
/ °C at 700 kPa)
+44.6 °F / +7 °C
2
Max. oil contents:
0.1 mg oil/m
3
/ 0.1 oz/ft
3
3
Max. concentration:
5 mg/m
3
/ 5 oz/ft
3
3
Max. particle size:
5
μ
m / 5 microns
Ambient conditions:
If low temperature powders are used, the ambient temperature may have to be lower than
86 °F (30 °C).
Volume measures:
For volumes, specified in Nm
3
(standard cubic meters). One cubic meter of a gas at
32 °F
(0 °C) and 1.013 bar is called norm cubic meter.
1 Nm
3
/h = 35.3 ft
3
/h; 1 bar = 14.504 psi
05/2007
0390860
– PEA-C4-HiCoat- Enamel
5