18
PEA-C4-HiCoat
OPERATING MANUAL
VERSION 05/2012
ORDER NUMBER DOC 390829
Dimensions:
Length/width/height
see chapter 5.3.1
Weight
555 g; 1.22 lbs
Electrical:
Input voltage
max. 22 Vpp
Input current
max. 0.9 A
Frequency
19 - 30 kHz
Output voltage
max. 100 kV DC
Polarity
negative
Construction type
in accordance with DIN EN 50177
type A-P
Protection class
IP 54
Pneumatic:
Input air pressure (atomizing air volume)
max. 3 bar; 0.3 MPa, 43.51 psi
Powder output quantity
max. 450 g/min; max. 0.99 lbs/min.
Ambient conditions:
Operating temperature range
5 - 45 °C; 41 - 113 °F
Relative humidity
< 75 %
5.3
TECHNICAL DATA
Outgoing air containing oil!
Risk of poisoning if inhaled.
Provide compressed air free from oil and water (quality standard
3.5.2 according to ISO 8573.1) 3.5.2 = 5 μm / +7 °C; 44.6 °F /
0.1 mg/m³.
WARNING
Ambient conditions:
If low-melting powders are used, the ambient temperature may have to be lower than
30 °C; 86 °F.
Volume measures:
for volumes specifi ed in Nm³ (standard cubic meters). One cubic meter of a gas at 0 °C;
32 °F and 1.013 bar is called norm cubic meter.