24
PEA-C4-HiCoat
A
P
E
P_01613
OPERATING MANUAL
VERSION 05/2012
ORDER NUMBER DOC 390829
Procedure:
1.
Switch off the high-voltage generation on the control unit.
2.
Mount the spray gun on the mounting bracket and attach both for example to
the gun support of the reciprocator.
Note:
For connecting and attaching the spray gun use the parts listed in chapter
"Accessories".
The distance of the installed spray guns to each other must be at least 300 mm;
11.81 inches for functional reasons.
3.
Connect the spray gun with the electrical cable to the control unit.
4.
Connect the powder feed hose to the spray gun and to the powder injector.
5.
Connect the atomizing air hose to the spray gun and to the control unit.
6.5
MOUNTING THE SPRAY GUN
Electrical connection of the control unit or
high-voltage generator
Atomizing air
Powder feed from the powder
injector
Ground the spray gun via the gun
support
Unintentional putting into operation!
Risk of injury.
Before any work on the device, in the event of work interruptions
and malfunctions:
Switch off the energy/compressed air supply.
Decompress spray gun and device pressure.
Secure the spray gun against actuation.
In the event of malfunctions, remedy the fault as described in
chapter "Troubleshooting".
WARNING