Procedure:
1.
Switch on the high-voltage generation and the powder feed.
Note:
To minimize the wear on the wearing parts, the total feed air and dosage air should be
under 5 Nm³/h!
The atomizing air should be adjusted for the
fl at spray nozzle to 0.1 Nm³/h
round spray nozzle to 0.2 Nm³/h
2.
Adjust the powder quantity and the powder speed on a test piece.
7.6