31
PEA-C4-HiCoat
30°
15°
0°
X
X
P_01095
P_01096
OPERATING MANUAL
VERSION 05/2012
ORDER NUMBER DOC 390829
7.8
REPRODUCIBLE SETTING OF THE NOZZLE POSITION
For a horizontal powder cloud, the
fl at spray nozzle is set where the
protective wedge is in the 0° position.
When attaching a round spray nozzle,
we recommend turning the protective
wedge in the 90° position to achieve
a smoother coating (the protective
wedge is now in the vertical position).
It is possible to change this position as
needed for special applications.
On the nozzle body and electrode holders
there are X markings. In 15° steps, the
position can be changed if necessary and
reproducibly.
The cap nut has to be removed for exact
positioning.
An adjustment tool is provided for the fl at
spray nozzle.
This allows all fl at spray nozzles to be
turned without damaging the electrodes
and without removing the cap nut.
The cap nut only has to be slackened.