37
PEA-C4-HiCoat
1
2
3
5
P_00591
P_00592
P_00593
OPERATING MANUAL
VERSION 05/2012
ORDER NUMBER DOC 390829
8.3
CLEANING THE SPRAY GUN AND DISMANTLING THE FLAT SPRAY NOZZLE
Procedure:
1.
Unscrew cap nut 1 from spray gun housing 5.
2.
Pull fl at spray nozzle 2 off the electrode holder 3.
3.
Carefully remove electrode holder 3 from gun housing 5.
Note:
Do not damage the electrode holder, when pulling out and
inserting.
4.
Remove powder residues from the parts removed and from
the spray gun.
Note:
Never place the spray gun or parts of the spray gun in cleaning
agent.
As a rule the protective wedge needs to be checked for wear and
replaced if necessary.
New protective wedge
Worn protective wedge
It is recommended to replace the protective wedge.
In the next section it is described how the protective wedge is to be dismantled and
inserted.