8.6.2
FITTING THE ANGLE ADAPTER
Procedure:
1.
Install electrode holder 1 together with nozzle
2 in the nozzle insert 3 and tighten cap nut 4.
2.
Push angle adapter 5 onto the gun body and
screw slightly threaded sleeve 6.
3.
Swivel angle adapter 5 in the desired position
and then tighten well threaded sleeve 6.
8.6.3
REPLACEMENT OF THE WEARING PARTS
Procedure:
1.
Loosen threaded sleeve 1 and separate angle
adapter 2 from gun body 3.
2.
Loosen cap nut 4.
3.
Pull out electrode holder 5 together with nozzle
6 of the nozzle insert 7.
Note:
Do not damage the electrode holder, when pulling