46
PEA-C4-HiCoat
P_01169
1
2
3
OPERATING MANUAL
VERSION 05/2012
ORDER NUMBER DOC 390829
8.8
CORONA-STAR FOR ANGLE ADAPTER
8.8.1
MOUNTING THE CORONA-STAR
Procedure:
1.
Switch off the high-voltage and the powder
feed and secure against inadvertent switch
on.
2.
Remove stopper from gun housing.
3.
Fit Corona Star for angle adapter 2 on angle
adapter (direction of fi tting shown is example
only).
4.
Fix the connection cable 3 on the spray gun
housing.
Note:
Check whether the grounding is assured.
5.
The spray gun is ready for use again.
Note:
Put stopper back into hole in gun housing when
converting the gun in the normal version without
angle adapter.
Danger from electric current!
Risk of injury and damage to the device.
Only trained personnel may modify the Corona-Star.
Prior to mounting the Corona-Star, the high-voltage and
the powder feed must be switched off and secure against
inadvertent switch on.
WARNING