Safety regulations
2. Safety
regulations
2.1 Safety
hints
010101_Sicherheit01_pea_em.doc
Warning
This equipment can be dangerous if it is not operated in accordance with
this operating manual!
There might be additional regulations to be observed, put into effect by
governmental, state or other official agencies or local security (fire)
departments!
Warning
Under no circumstance may persons with a cardiac pacemaker come close
to the area between the tip of the spray gun and the work piece to be
coated!
The following rules must be observed in order to ensure a safe and efficient use of the
equipment:
•
The user has to observe particularly the safety
guidelines of the VdS, the local professional and
security institutions.
•
The electrostatic coating equipment may only be
operated by trained and qualified personnel.
•
The spray gun may only be operated in powder
coating booths or on powder coating stands that
are equipped with a ventilation system.
•
Over sprayed powder must be reliably collected.
•
Adhere to the instructions given by the manufac-
turers and to the prevalent local laws on the
environment when disposing of waste coating
powder.
•
The main power connection for operation of the
Wagner powder equipment
must
be electrically
interlocked with the exhaust system of the
powder coating booth.
•
In the event of faults or defects, repair work is to
be performed at the user's discretion.
•
Repairs may only be carried out by trained
technicians.
•
The work area must have an electrostatically
conductive floor. (measured in accordance with
EN 1081)
•
All conductive parts in the work area must be
electrostatically grounded. (work area = 1 m
around every spray location or opening in the
booth)
•
All persons inside the work area must wear elec-
trostatically conductive footwear.
•
Spray guns should be operated with bare hands!
If gloves are used they
must
be made of
conductive material.
6
0390860
– PEA-C4-HiCoat-Enamel
05/2007