16
PEM-C4-Ergo
.
P_00935
P_00694
P_00694
P_00694
OPERATING MANUAL
VERSION 02/2009
ORDER NUMBER DOC2305054
5.1
PREPARING THE SPRAY GUN
5
START-UP
5.1.1
SELECTION OF THE SUITABLE NOZZLE SYSTEM
Nozzle
Overview Application
Spray pattern
Fan spray nozzle
Diffi cult workpieces
●
Undercuts
●
Profi les
●
Flat workpieces
(reduced picture frame)
Widely spread fl at powder
cloud
Defl ector cone
●
Wire goods
●
Grid designs
Oval powder cloud:
Size of the powder cloud is
dependent on the defl ector
cone diameter
Nozzle
Application
Distance to
workpiece
(mm)
Powder
output
(g/min)
F1¹
Universal application
(slow powder cloud)
●
Deep and complex shapes
●
Extensive workpieces
120 … 300
50 … 250
F2¹
Targeted application
(dense powder cloud)
●
High penetration
●
Wide coating range
120 … 400
30 … 200
WARNING
Incorrect installation/operation!
Risk of injury and damage to equipment
When putting into operation and for all work, read and follow
the operating instructions and safety regulations for the addi-
tionally required system components.
SIHI_0050_GB