8.4.2 FITTING THE FLAT JET NOZZLE
Procedure:
1. Before inserting the electrode holder, the spring contact of
the gun body and contact surface of the electrode holder
should be checked.
2.
4.
3.
P_01674
The spring contact must be clean and smooth-running, the
gun body must also be clean and free of powder deposits.
2. Insert electrode holder into gun housing.
3. Attach flat jet nozzle to electrode holder and attach union nut.
4. Screw union nut onto gun housing until flat jet nozzle can
no longer be turned by hand.