37
Plast Coat 25 · 35
GB
placIng Into operatIon
Preparing the mortar spraying machine
Only work with the safety grill inserted!
Recommended lubricant for the mortar hose
Water is not a satisfactory lubricant.
Danger of blockages!
Synthetic resin products –> synthetic resin
dispersion
PCC systems
–> cellulose paste
Spray lance with automatic control
• Open material tap (3, fig. 15) on the spray lance. The mortar
spraying machine will switch on.
Spray lance without automatic control
• Open material tap (3, fig. 16) on the spray lance. Press remote
control switch (1, fig. 16). The mortar spraying machine will
switch on.
Spray lance with automatic control
• When the synthetic resin dispersion or cellulose paste has
been pumped into the mortar hose – turn off device, turn
switching sleeve (1, fig. 15) by 90° in a clockwise direction as
far as it will go.
• Close material tap (3, fig. 15).
extension cable PlastCoat 25
The cross section of the cable must be min.
3 x 2.5 mm. Unwind extension cable com-
pletely. Make sure that the couplings and
plugs are in complete working order.
Arrange the mains cable so that there is no
danger of it being tripped over.
Protect against damage, e.g., caused by it
being run over.
• Before connecting to the mains make sure that the mains
voltage is in accordance with the details on the rating
plate.
• Only connect to the mains supply using a special distribut
-
ing point, e.g. using a site distribution system with fault cur-
rent protection with INF ≤ 30 mA.
• Connect mortar spraying machine to the mains supply.
• Fill 2–3 l synthetic resin dispersion or cellulose paste into the
receptacle.
•
Caution:
set changeover switch (4, fig. 14) to „0“ before turn-
ing on the master switch (1, fig. 14).
the pump is switched on, even if the feed rate
regulator is at position „0“.
• Turn master switch (1, fig. 14) to „1“, the indicator lamp will
show that the machine is ready for operation.
• Set feed rate regulator (3) to „5“.
• Turn changeover switch (4) to „AUTO“ (remote control using
spray lance).
• Hold spray lance over an empty bucket.
7
1 6
2
8
3
5
4
extension cable PlastCoat 35
The cross section of the cable must be min.
5 x 2.5 mm. Unwind extension cable com-
pletely. Make sure that the couplings and
plugs are in complete working order.
2
3
4
1