69
Prima Sprint
.
5
4
3
2
1
P_01097
OPERATING MANUAL
VERSION 07/2009
ORDER NUMBER DOC 2305835
7.2
CHECKING THE PEM-C4-ERGO CORONA MANUAL GUN
7.2.1
REPLACING THE SPRAY GUN
Before you commence the replacement of the spray gun any powder residue must be
removed thoroughly.
The wearing parts in the spray gun, marked in the spare parts list with ”
◆
”, must be
regularly checked and, if necessary replaced.
Procedure:
1. Switch off the control unit and/or the high-voltage generator.
2. Disconnect the electrical cable 1 from the control unit 2.
3. Disconnect the hoses for powder feed 3 and atomizing air 4 from the spray gun 5.
4. Connect the hoses for powder feed 3 and atomizing air 4 to the new spray gun 5.
5. Connect the electrical cable 1 to the control unit 2.
6. The spray gun is ready for use again.