8
ProSpray 20
Voltage
100-110 VAC~, 50/60 Hz or
220-240 VAC~, 50/60 Hz
Max. current consumption
100-110 VAC~
220-240 VAC~
11.0 A
5.9 A
Rated input of device
900 W
Power Cord
6 m long, 3 x 1.5 mm²
Max. operating pressure
214 bar (21.4 MPa)
Max. volume flow
2.0 l/min
Volume flow at 12 MPa
(120 bar) with water
1.60 l/min
Max tip size
0.021 inch – 0.53 mm
Max. temperature of the coating material
43°C
Max viscosity
20.000 MPa·s
Weight
15.2 kg
Special high-pressure hose
6,35 mm, 15 m - 1/4” - 18 NPSM
Dimensions (L X W X H)
480 x 360 x 405 mm
Vibration
Spray gun does not exceed 2.5m/s
2
Max sound pressure level
80 dB*
* Place of measurement: 1 m distance from unit and
1.60m above floor, 12 MPa (120 bar) operating pressure,
reverberant floor
4
REPAIRS AT THE UNIT
Switch the unit OFF.
Before all repair work: Unplug the power plug
from the outlet.
4.1
RELIEF VALVE
Attention
The valve housing (4) should not be repaired. If
worn, it should always be replaced with a new
one.
1.
Use a drift punch of 2 mm to remove the grooved pin (Fig.
8, Item 1) from the relief valve handle (2).
2.
Remove the relief valve handle (2) and cam base (3).
3.
Using a wrench, remove the valve housing (4) from the
pump manifold (6).
4.
Ensure that the seal (5) is seated correctly, then screw the
new valve housing (4) completely into the pump manifold
(6). Tighten securely with a wrench.
5.
Align the cam base (3) with the hole in the pump manifold
(6). Lubricate the cam base with grease and slide on the
cam base.
6.
Bring the hole in the valve shaft (7) and in the relief valve
handle (2) into alignment.
7.
Insert the grooved pin (1) to secure the relief valve handle
in position.
1
7
5
4
2
3
6
GB
3
TECNICAL DATA
Summary of Contents for PROSPRAY 20
Page 2: ......
Page 13: ...13 ProSpray 20 GB...