37
PROTEC 2K
B_03913
1
3
2
B_03703
4
B_05635
2
3
1
OPERATING MANUAL
VERSION 02/2016
ORDER NUMBER DOC2352824
5.9
STROKE COUNT (OPTION)
Each air motor has a 1/8" air connection with which the air pressure in the lower air motor
chamber can be measured. This signal can be used for counting the strokes in an external
control, for example.
The pressure signal corresponds to the set working air pressure and is available during the
complete upwards stroke of the pump. If both of the signal fl anks are evaluated, the upper
and lower reversal point can be determined. A 4/2-mm; 0.16/0.08-inch air hose is used as
an air signal line.
Pos
Order No. Designation
1
9998675
Threaded plug
2
9999066
Male stud elbow
3
9982072
Air hose (per meter)
4
9943049
Pneumatic pre-selection counter
The component B is fi tted with a 2K PC relief
combination.
1
Fluid section B connection
2
Product outlet
3
Return line
5.8.2
2K PC RELIEF COMBINATION, 530 BAR
53 MPa
530 bar
7687 psi
Closed
Open