8.2.3.3
FILLING WITH SEPARATING AGENT
Piston pump dry run!
High wear/damage to the packings.
Paint or solvent can escape if the seals are dry.
Ensure that the separating agent tank is fi lled with suffi
cient separating agent.
Filling level 1 cm; 0.4 inch under the cup edge.
NOTICE
2K pump
Check the separating agent every day in both fl uid
sections, and top up if necessary.
1. See through the cover of the connection part air
motor fl uid section (11). Ensure that the pistons of
the pump is not in the lowest position.
Check in the opening of the fl uid section the
separating agent level.
2. Fill separating agent via two hermetic connections
(see fi gure).
Filling level:
1 cm; 0.4 inch under the edge.
Separating agent: Order No. 9992504
Inclination angle of the pump
Maximum permissible inclination of pump for
moving, transportation, etc. ± 10°.
The pump must be vertical during operation.
Flushing pump
Fill separating agent of fl ushing pump:
See fl ushing pump's operating manual.
8.2.3.2
DRAINING CONDENSATE FROM WATER SEPARATOR
Frequently drain the condensate that may accumulate in the water separator (22).
Make sure the water level in the fi lter cup never reaches the max. level marked on
the cup itself.
Summary of Contents for PROTEC 2K
Page 2: ......
Page 21: ...21 PROTEC 2K OPERATING MANUAL VERSION 02 2016 ORDER NUMBER DOC2352824...
Page 38: ...38 PROTEC 2K OPERATING MANUAL VERSION 02 2016 ORDER NUMBER DOC2352824...
Page 110: ...110 PROTEC 2K OPERATING MANUAL VERSION 02 2016 ORDER NUMBER DOC2352824...
Page 120: ...120 PROTEC 2K OPERATING MANUAL VERSION 02 2016 ORDER NUMBER DOC2352824...
Page 131: ......