19
GM 1-350/530
B_5054
B_5303
OPERATING MANUAL
VERSION 02/2015
ORDER NUMBER DOC2349369
7.3.5
ELIMINATE NOZZLE CLOGGING
1.
Relieve the pressure on the spray gun and product pressure generator in accordance with Chapter 7.3.2.
2.
Secure the spray gun with the locking device.
3.
Rotate the reversing nozzle 180° so that its tip is pointing opposite the direction of spray.
Attention: when rotating the reversing nozzle, always aim the spray gun at the fl oor, as product can still
come out due to product being trapped between the reversing nozzle and the valve seat.
4.
Briefl y trigger the spray gun so that the pressure eliminates the clog.
Note:
Only activate the trigger briefl y if the nozzle is installed in the reversed direction.
7.3.6
HORIZONTAL/VERTICAL SPRAYING
1.
Secure the spray gun with the locking device.
2.
Turn the nozzle holder to the desired position.
Attention:
always turn the nozzle holder clockwise (see illustration) so that the threaded connection
cannot become loose. After turning, check whether the nozzle holder is tight. If not, tighten.
Horizontal spraying
Vertical spraying