17
OPERATING MANUAL
VERSION 07/2017
ORDER NUMBER DOC 2349369
6.6
COMMISSIONING
6.6.1 PREPARATION
NOTICE
Impurities in the spraying system!
Spray gun blockage, products harden in the spraying system.
Flush the spray gun and paint supply with a suitable flushing agent.
6.6.2 PROCEED
1. Secure the spray gun.
2. For spray guns with filters , insert a suitable filter (filter insert, see Chapter
).
3. Connect the product hose to the spray gun and product supply system.
4. - Insert nozzle holder PT-HD GM1: Set of seals (saddle and seal) into the nozzle
holder. Push in nozzle. Screw the entire nozzle holder onto the spray gun. Tighten
nozzle holder using a size 30 wrench (SW 30).
- Nozzle holder WAGNER Tip 7/8 UNF: Insert seal in nozzle holder, screw nozzle
holder onto spray gun and push in nozzle according to supplement WAGNER Tip
(For Order No., see Chapter
).
- Anti-contact guard 7/8 UNF: Insert nozzle in anti-contact guard. Insert seal. Screw
the entire nozzle holder onto the spray gun. Tighten nozzle holder using a size 27
wrench (SW 27).
5. Visually check the permissible pressures for all the system components.
6. Make sure that the device and all other conductive parts within the work area are
grounded.
7. To perform a leak test on the entire installation, the pressure is slowly increased
using a suitable medium, step by step, until the maximum pressure indicated on the
type plate is reached.
Note:
- Set the operating pressure to 100 bar; 10 MPa; 1450 psi.
- Pull the trigger and check whether the gun closes cleanly upon release.
8. Relieve the pressure of the spray gun and product pressure generator and secure
the spray gun.
6.6.3 VERIFYING A SAFE OPERATIONAL CONDITION
A skilled person must check to ensure that the device is in a reliable state after it is
installed and commissioned.
This includes:
- Carry out a safety checks in accordance with Chapter
.