Operating manual Manual Powder System SPRINT XE
6 Assembly and Commissioning
32
Order number 2354920 | Edition 01/2023
6.6.1 Grounding the powder coating system
P_01827
1
2
4
7
8
6
5
3
1
Only use mains cables with grounding strand!
2
Connect the trolley's grounding cable to the grounding connection of the control unit!
3
Connect the control unit's grounding cable with the signal ground!
4
Connect grounding cable to an uncoated metal part of the booth!
5
Remove all paint from hooks and other hanger parts!
6
Wear electrostatically conductive gloves!
7
Wear electrostatically conductive footwear!
8
The floor must be electrostatically conductive!
6.7 SAFETY CHECKS
A skilled person must check to ensure that the device is in a reliable state after it is
assembled and commissioned. This includes:
4
Carry out safety checks in accordance with Chapter Safety Checks [
45].