Super Finish 27 • 31
35
GB
Interruption of work
11. Clean suction pipe for about three minutes.
12. Rinse in circuit – set multifunction switch to
(ON).
13. Close spray gun.
14. When cleaning with water, repeat procedure for about three
minutes with clear water.
15. Switch off unit – set multifunction switch to (OFF).
Achtung
The effect of cleaning is increased if the
spray gun is alternately opened and closed.
Achtung
In case of coating materials diluted with
water, warm water improves cleaning.
•
Unit with upper hopper
1. Fill upper hopper with suitable cleaning agent.
2. Switch on unit, set multifunction switch to
(ON -
circulation).
3. Operate unit for a few minutes in circuit with spray gun
closed (without tip).
4. Set multifunction switch to
(spray).
5. Pull trigger guard on spray gun.
6. Pump cleaning agent into a separate, open container until
the unit is empty.
Attention
In the case of coating materials containing sol-
vents, the container must be earthed.
Danger
Caution! Do not pump or spray in container
with a small opening (bunghole)!
See safety regulations.
7. Switch off unit, set multifunction switch to (OFF).
7.
INTERRUPTION OF WORK
1. Switch off unit, set multifunction switch to
(pressure
relief, circulation), then to (OFF).
2. Secure spray gun, see operating manual for spray gun.
3. If the tip is to be cleaned, see page 47, point 13.2.
4.
Unit with suction system
Leave the suction system submerged in the coating
material or submerge it into the appropriate cleaning agent.
Suction filter and unit should not dry out.
Attention
In using quick-drying - or two-component
coating material, do not fail to rinse unit
through with a suitable cleaning agent during
the processing period.
8.
CLEANING UNIT
(SHUTTING DOWN OPERATION)
Cleanliness is the surest guarantee for disturbance-free opera-
tion. Always clean the unit after completing spraying work. In
no event may residue of the coating material dry and collect
in the unit. The cleaning agent used for cleaning (only with
a flash point of over 21 °C) must correspond to the coating
material.
•
Secure spray gun,
see operating manual for spray gun.
Dismount tip and clean, see page 47, point 13.2.
•
Unit with suction system (fig. 12)
1. Remove suction system from the material vessel, e.g. put
unit in the horizontal set-up position.
2. Switch on unit, set multifunction switch to
(ON–
circulation) and further to
(spray).
3. Pull the trigger guard on the spray gun in order to pump
residue coating material from the suction pipe, the high-
pressure hose and the spray gun into an open container.
Attention
In case of coating material containing solvents,
the vessel must be earthed.
Danger
Caution! Do not pump or spray in container
with a small opening (bunghole)! See safety
regulations.
4. Submerge suction system in a suitable cleaning agent.
5. Set multifunction switch to (OFF).
6. Screw on spray gun on suction pipe (fig. 12) with the two
accompanying spanners 22 mm.
7. Set multifunction switch to
(ON – circulation).
8. Pump suitable cleaning agent in the circuit for approx.
1 minute.
9. Pull trigger guard on spray gun and hold with clamp.
10. Set multifunction switch to
(spray).