44
TempSpray-H326 / -H226 / -H126
9.4
REMEDY IN CASE OF FAULTS
DISPLAYED ERROR CODE
POSSIBLE CAUSE
MEASURES FOR ELIMINATING THE MALFUNCTION
Err0
Residual current exceeded (approx. 33mA) and
relay cuts out:
•
Heating conductor insulation in hose dam-
aged
•
Cable has come loose
•
Water has penetrated device
Please contact Wager Customer Service
Err1
Electronics defective - no communication be-
tween the boards
Disconnect the device from the power supply.
Wait approx. 30 seconds and switch it back on.
If the error code is still displayed, contact Wag-
ner Customer Service.
Err2
Control board does not receive any feedback
Disconnect the device from the power supply.
Wait approx. 30 seconds and switch it back on.
If the error code is still displayed, contact Wag-
ner Customer Service.
Err3
Interface board does not receive any feedback
/no information is received by the interface
board
Cables pinched in housing
Disconnect the device from the power supply.
Wait approx. 30 seconds and switch it back on.
If the error code is still displayed, contact Wag-
ner Customer Service.
Have a skilled electrician open the housing
and check the cables.
Err4
Heating resistance too large:
Current flow in heating conductor is inter-
rupted
Overtemperature protection has actuated
Disconnect the device from the power supply.
Wait approx. 30 seconds and switch it back on.
If the error code is still displayed, contact Wag-
ner Customer Service.
Err5
Heating resistance too small:
Short-circuit in heating wire
Disconnect the device from the power supply.
Wait approx. 30 seconds and switch it back on.
If the error code is still displayed, contact Wag-
ner Customer Service.
Temperature is displayed
in °F instead of °C
Temperature display converted to Fahrenheit
Press „START“ and „
“ simultaneously to con-
vert the display to °C.
In the case of all abovementioned errors, a
task that has been started can still be fin-
ished with the TempSpray heating system
switched off.
GB
REMEDY IN CASE OF FAULTS