31
VERSION 01/2021
ORDER NUMBER DOC2422004
TOPFINISH Bell 1S ECH
A
B
C
D
B_01138
F
E
G
B_01332
Designation
A Spray booth
B Work piece
C Conveyor
D Control cabinet
E Reciprocator
F Electrostatic high rotation atomizer
G Air filter
6.7
SETTING UP STATIONARY ELECTROSTATIC SYSTEMS
The high-speed rotary atomizer is a component of a stationary coating system. When
setting up permanent coating systems, EN 50176 (ignitable coating products) or EN 50348
(non-ignitable coating products) must be observed. One of the requirements is that
activation of the high voltage is only possible by using a key. But it must be possible to
switch off the high voltage without a key.
If using ignitable coating products (category 3G), requirements include a safe shutdown
after the first spark discharge at the latest.
DANGER
Exploding gas air mixture due to a sparkover!
Danger to life from flying parts and burns.
Ground all device components.
Ground the work pieces to be coated.
Observe the minimum distance between the atomizer bell, the grounded unit
components and the work pieces to be coated. The minimum distance is 250 mm;
9.84 inch.