Preparing the spray gun
03/2008
351874
- PEA-T3
9
2.2
Connecting the spray gun
Before you commence connecting the gun, switch off the powder feed. For information on this
activity refer to the related operating instructions for the control units and control modules.
Hint
Use the parts listed in chapter
9
"
Accessories
" for connecting and fastening the spray
gun.
The spacing between the spray guns when fitted must be at least 300 mm.
A
T
P
E
Electrical connection
Powder feed
Grounding the spray gun
via the gun support
Atomizing air
Tribo air
from powder injector
from control unit
Mount the spray gun on the hanger and secure both, for example on the gun holder of the
reciprocator. If an oscillator is being used, the spray gun must be fixed with a clamping
element (see accessories).
Connect the spray gun to the Tribo current measuring or display module with the electrical
cable
E
.
Connect the powder feed hose
P
to the spray gun.
Connect the hose for Tribo air
T
and the hose for atomizing air
A
to the spray gun.
Hint
By using a Wagner
PI-F1
powder injector and a suitable control unit, it is
possible to blow out or flush the spray gun automatically each time before it is switched
off.