13
VM 5000
Typ / Type:
VM 5000
115VAC - 230VAC
50Hz / 60Hz
2307317
max. 40W
J. WAGNER AG
Industriestrasse 22
CH - 9450 Altstätten
Made in Switzerland
Serie Nr.:
Serial No.:
Spannung:
Voltage:
Artikel Nr.:
Article No.:
Eingangsleistung:
Input Power:
Schutzklasse:
Protection Class:
Norm:
Standard:
EN 50050
IP 54
Spannung:
Voltage:
Strom:
Current:
max. 20Vpp
max. 1,0A
Eingangsstrom:
Input Current:
max. 0.5A
I
0
Main Switch
Nicht unter Spannung trennen!
Do not disconnect under voltage!
Prim.
1.0 AT
0102
II (2) G
SIRA 11 ATEX 5374X
II 3 G
Ex nR IIA T4 Gc
1
2
4
5
6
7
8
9
10
11
12
18
13
14
15
22
16
17
21
19
20
B_04389
3
OPERATING MANUAL
EDITION 08/2014
ORDER NUMBER DOC2318718
3.3
TYPE PLATE
1 Identifi cation for category 3 (zone 2)
2 Identifi cation for category 2 (zone 1)
3 Test center
4 Device type
5 Article number
6 Serial No.
7 Input voltage
8 Input power
9 Input current
10 Protection class
11 Standard
12 Do not disconnect under voltage!
13 Primary fuse 1.0 ampere slow-acting
14 Mains supply switch
15 Gun connection
16 Maximum voltage
17 Maximum current
18 Grounding
19 Never spray device parts using electrostatic
equipment (electrostatic spray gun!).
20 Use only a damp cloth to clean the unit.
Remove deposits from the surfaces.
21 Do not dispose of used electrical equipment
with household refuse.
22 Interface
Summary of Contents for VM 5000
Page 2: ......
Page 42: ...42 VM 5000 OPERATING MANUAL EDITION 08 2014 ORDER NUMBER DOC2318718...
Page 65: ...65 VM 5000 OPERATING MANUAL EDITION 08 2014 ORDER NUMBER DOC2318718...
Page 66: ...66 VM 5000 OPERATING MANUAL EDITION 08 2014 ORDER NUMBER DOC2318718...
Page 67: ...67 VM 5000 OPERATING MANUAL EDITION 08 2014 ORDER NUMBER DOC2318718...