36
VM 5000
EXT
100
80
60
40
20
μA
80
60
40
20
10
kV
R3
R1
R2
VM 5000
B_03682
EXT
100
80
60
40
20
μA
80
60
40
20
10
kV
R3
R1
R2
VM 5000
B_03682
_16
15
9
16
_15
15
19
20
OPERATING MANUAL
EDITION 08/2014
ORDER NUMBER DOC2318718
7.4.2
SETTING THE CURRENT LIMITATION
The "Current Limitation" bar graph display (9) is located above the "Current Limitation"
push button (19). If the control unit is in the ready position, this light strip shows the set
value as a dot.
The current limitation is an adjustable threshold. If this threshold is exceeded, for example,
by the spray gun having approached the object being sprayed, the high-voltage is adjusted
downwards until the threshold is no longer exceeded.
The set values for high-voltage (40 kV) and for spray current limitation (83 mA) that are
shown in the examples, are saved in R2 by pressing and holding for a longer time the
recipe push button (for > 2 seconds).
Procedure:
1. Press the "Current Limitation"
button (19) to adjust the limitation
of the spray current.
The LED (20) indicates that current
limitation is selected.
2. The current limitation can now be
adjusted with the universal control
dial (16) between 10 - 100 µA with a
resolution of 1 µA.
The corresponding value is
indicated in the LED display (15).
Summary of Contents for VM 5000
Page 2: ......
Page 42: ...42 VM 5000 OPERATING MANUAL EDITION 08 2014 ORDER NUMBER DOC2318718...
Page 65: ...65 VM 5000 OPERATING MANUAL EDITION 08 2014 ORDER NUMBER DOC2318718...
Page 66: ...66 VM 5000 OPERATING MANUAL EDITION 08 2014 ORDER NUMBER DOC2318718...
Page 67: ...67 VM 5000 OPERATING MANUAL EDITION 08 2014 ORDER NUMBER DOC2318718...