Explosive powder/air mixes!
Danger to life and damage to the device.
Before starting the cleaning, de-energize the device.
Only electrically conductive tanks may be used for cleaning and
fl ushing agents. Earth the tank.
Clean the control unit with non-fl ammable cleaning agent.
Ensure that no electric component is cleaned with or immersed
into solvent.
DANGER
Incompatibility of cleaning/fl ushing agent and working
medium!
Risk of explosion and danger of poisoning by toxic gases
Examine the compatibility of the cleaning and fl ushing agents
and working media on the basis of the safety data sheets.
WARNING
Cleaning the control unit
If there are deposits on the surfaces, the device may form electrostatic charges. Flames or
sparks can form during discharge.
Remove deposits from the surfaces to maintain conductivity.
Only use a damp cloth to clean the device.