GB
26
W 150
Problem
Cause
Remedy
Too much fog of
coating material
(Overspray)
•
Distance to the object too large
•
Too much coating material
applied
➞
Reduce distance
➞
Turn material volume
adjusting screw to the
left (-)
Paint in the
ventilating hose
•
Diaphragm soiled
•
Diaphragm defective
➞
Clean the diaphragm
➞
Replace the diaphragm
18. Technical Data
Technical Data
Max. viscosity
100 DIN-s
Power source
230 V
~
, 50 Hz
Power consumption
300 W
Atomizing output:
70 W
Max. flow rate:
140 ml/min
Protection Class:
I
Sound pressure level*
75 dB (A); Uncertainty K = 4 dB
Sound pressure output*
86 dB (A); Uncertainty K = 4 dB
Oscillation level*
< 2.5 m/s²; Uncertainty K = 1.5 m/s²
Weight
1.2 kg
* Measured in accordance with 50580:2014
Information about the oscillation level
The specified oscillation level has been measured according to a standard test
procedure and can be used to compare against electric tools.
The oscillation level is also for determining an initial assessment of the vibrational strain.
Attention!
The vibration emission value can differ from the specified value when the
electric tool is actually in use, depending on how the electric tool is being used. It is
necessary to specify safety measures to protect the operating personnel. These measures
are based on an estimated shutdown during the actual conditions of use (all parts of the
operating cycle are taken into consideration here, for example periods when the electric
tool is switched off, and, when it is switched on but running without any load).
Summary of Contents for W 150
Page 1: ...wagner group com D GB NL F WOOD METAL SPRAYER W 150 ORIGINAL BETRIEBSANLEITUNG...
Page 3: ...W 150 click c d 2 1 A B C...
Page 4: ...W 150 5 15 cm g A B 14 13 15 18 4 3 1 2 3 4 C...
Page 5: ...W 150 13 12 14 6 1 2 11 5 4 3 10 9 8 7 1 1 2...
Page 6: ...W 150 D 1 14 15 28 29 42 43 56 58 GB NL F Fragen Questions Des questions Vragen...