ATTENTION!
Air in the suction hose or pump area can lead to suction and function interruptions. Ensure that the suction
filter is always completely covered with paint. Refill paint in a timely manner, set the paint container at an
angle or prepare a new paint container. Switch off the unit before moving the suction hose to a new paint con-
tainer.
Remedy for sucked-up air
Open air bleed valve (figure 5, A) and let unit run for approx. 1 minute until paint exudes from the air bleed
hose. Hold hose over paint container when doing so. Close air bleed valve. If malfunction is still present:
repeat procedure.
Breaks during work
Short breaks (up to four hours):
1.
Switch off paint pump and open dosage unit in handle.
2.
Insert paint roll into plastic bag immediately and tie it up airtight (figure 6, A).
3.
Leave suction and air bleed hoses in the paint.
Long breaks (days):
1.
Place paint roll in a bucket of water (figure 6, B).
2.
Wet the paint surface in the paint container with some water to prevent a skin from forming.
3.
Used accessories which are already unscrewed are to be placed into water immediately after use.
Shutting down and cleaning
1.
Scrape off paint roll over the paint container.
2.
Remove paint roll by snapping it from the roller frame and clean it thoroughly separately. Detach the seal-
ing cap of the paint roll with a suitable tool. Detach paint roll and clean all parts in lukewarm water.
3. Remove suction hose from the paint container and submerge it in a second container filled with water.
Hold roller frame above paint container or hang it there. Switch on the unit and pump water up to the
roller frame. The remaining paint in the system is pumped back into the paint container.
4. Switch off the feed pump and unplug the power plug from the outlet!
5. Wipe paint off suction hose and air bleed hose.
6.
Pull off filter and clean it thoroughly.
7. Place roller frame with paint feed hose in a second container or sink.
8.
Fit air bleed hose onto cleaning adapter (figure 7).
9. Open air bleed valve completely (figure 5, A).
10. Fit cleaning adapter onto faucet and rinse system out until clean water exits at the roller frame
- approx. one minute - (figure 12).
11. Close air bleed valve (figure 5, B).
12. Slide suction hose onto the cleaning adapter (figure 8).
13. Fit cleaning adapter onto faucet and rinse system out until clean water exits at the roller frame
(approx. one minute).
Cleaning the valve unit
1.
Screw off deaeration unit, remove suction head and pull out valve unit (figure 9).
2. Thoroughly clean points (figure 10, A + B + C) with a soft brush and water.
3. Press the valve disk against the seating with a screwdriver and turn left and right. This rubs off any
existing paint particles (figure 11).
4. Before inserting the valve unit, lightly lubricate the seal rings (figure 10, A).