5) Insert the suction tube with container seal in the gun body.
In order to mount the gun more easily apply lubricating grease (enclosed) liberally
to the O-ring at the gun front part (Fig. 18, 4).
17. Maintenance
Air filter
WARNING!
Never operate the machine without the air filter; dirt could be sucked
in and interfere with the function of the machine.
Disconnect plug before changing parts.
•
Change the air filter if it is soiled.
•
For this pull the air filter out of the unit (Fig. 17).
•
Insert a new air filter into the compartment.
Ventilating hose / Valve
1) Pull the ventilating hose (Fig. 12, 1) at the top from the gun body. Screw off the valve
cover (2). Remove the diaphragm (3).
Carefully clean all parts or replace in the
event of damage.
2) Place the diaphragm (Fig. 12, 3)
with the pin facing upwards
on the bottom section
of the valve. Also see the marking on the gun body.
3) Place on the valve cover (Fig. 12, 2) and screw it closed.
4) Place the ventilating hose (Fig. 12, 1) on the valve cover and on the nipple at the gun
body.
18. Spare Parts
Spare Parts List (Fig. 18)
Pos. Name
Order No.
1
Wall Extra I-Spray spray attachment incl. 1300 ml container
2361 746
2
Air cap
2382 753
3
Union nut and nozzle
2382 751
4
O-ring
2362 875
5
Ventilating hose, valve cover, diaphragm
2382 754
6
Suction tube
2389 021
7
Container seal
2389 023
8
Container with cover 1300 ml (only for Wall Extra I-spray
spray attachment)
2305 155
9
Handle
0414 911
10
Air hose
2308 501
11
Carrying belt
2322 299
12
Air filter
2308 502
13
Feed hopper (3 pcs.)
2304 028
Summary of Contents for W 450
Page 1: ...wagner group com D GB NL F WALL SPRAYER W 450 ORIGINAL BETRIEBSANLEITUNG ...
Page 3: ...W 450 4 a b click 5 A B 3 ...
Page 4: ...W 450 20 30 cm 10 1 2 6 A B 7 1 8 1 11 9 a b ...
Page 5: ...W 450 1 2 3 12 1 2 3 13 4 14 2 15 1 2 2 16 ...
Page 6: ...W 450 17 ...
Page 8: ...W 450 66 1 15 D 16 30 GB 31 46 F 47 62 NL Fragen Questions Des questions Vragen ...
Page 72: ...64 W 450 ...
Page 73: ...65 W 450 ...