Problem
Cause
Remedy
No coating material emerges
Nozzle clogged
Clean
from the nozzle
Feed tube clogged
Clean
Material volume setting turned too far to
the right (-)
Turn to the left (+)
Feed tube loose
Insert
No pressure build-up in container
Tighten container
Coating material drips from the
Nozzle loose
Tighten
nozzle
Nozzle worn
Change
Nozzle seal worn
Change
Coating material build-up on air cap and
nozzle
Clean
Atomisation too coarse
Viscosity of coating material too high
Thin
Material volume too large
Turn mat. vol. adjusting screw
to the right (-)
Material volume adjusting-screw turned too
far to the left (+)
Nozzle contaminated
Clean
Air filter heavily soiled
Change
Too little pressure build-up in container
Tighten container
Spray jet pulsates
Coating material in container running out
Refill
Air filter heavily soiled
Change
Coating material causes
Too much coating material applied
Turn material volume adjusting
“paint tears”
screw to the right (-)
Too much fog of coating
Distance to the object too large
Reduce distance
material (Overspray)
Too much coating material applied
Turn material volume adjusting
screw to the right (-)
Correction of Malfunctions
Summary of Contents for W 650
Page 1: ...W 650 D GB F NL 2 Jahre GARANTIE 2 years WARRANTY 2 ans de GARANTIE 2 yaar GARANTIE ...
Page 2: ...1 1 2 7 8 3 6 5 4 13 12 9 10 11 2 a b 0209058 0050342 14 ...
Page 3: ...3 7 5 6 4 a b B A A B C 8 2 1 ...
Page 4: ...5 15 cm 10 a b 12 9 11 A B 1 Luftdüse Airnozzle Buse d air Luchtblaashulpstuk ...
Page 5: ...13 1 2 3 4 11 12 10 14 5 8 6 7 9 13 5 ...
Page 6: ...W 650 25 31 17 24 9 16 1 8 32 33 D GB F NL ...
Page 38: ......