background image

2

W 690 Flexio Extra Spray Kit

AUS

1. Explanation of symbols used

This symbol indicates a potential danger for you or for the device. 

Under this symbol you can find important information on how to 

avoid injuries and damage to the device.

Danger of electrical shock

i

Indicates tips for use and other particularly useful information.

2. General Safety Instructions 

Caution!  

Read all the instructions. Non-observance of the instructions below can cause 

electric shock, fire and or serious personal injuries. The term "power tool" used 

below covers both mains-operated power tools (with mains lead) and 

accumulator-operated power tools (without mains lead).

 

1. Safety at the workplace 

a) Keep your workplace clean and well lit. 

Disorder or unlit workplaces may result in 

accidents. 

b) Never use the tool in hazardous areas that contain flammable liquids, gases 

or dusts. 

Power tools generate sparks that can ignite the dust or vapors. 

c) Keep children and other persons away when using the power tool. 

You can 

lose control of the tool if you are distracted. 

2. Electrical Safety 

a) The tool plug must fit into the socket. The plug may not be modified in any form. 

Do not use adaptor plugs together with protective-earthed tools. 

Unmodified 

plugs and suitable sockets reduce the risk of an electric shock.

 

b) Avoid physical contact with earthed surfaces such as pipes, heating elements, 

stoves and refrigerators. 

The risk through electric shock increases if your body is 

earthed.

 

c) Keep the equipment away from rain and moisture. 

The risk of an electric shock 

increases if water penetrates electrical equipment.

 

d) Do not misuse the mains lead by carrying the tool by the lead, hanging it from 

the lead or by pulling on the lead to remove the plug. Keep the lead away from 

Summary of Contents for W 690 Flexio

Page 1: ...wagner group com UNIVERSAL SPRAYER W 690 FLEXIO EXTRA SPRAY KIT OPERATING INSTRUCTIONS AUS...

Page 2: ...W 690 Flexio Extra Spray Kit a 11 10 12 17 8 9 7 4 6 3 1 2 16 14 15 20 13 21 18 19 5 22...

Page 3: ...W 690 Flexio Extra Spray Kit A B 1 2 3 B A...

Page 4: ...W 690 Flexio Extra Spray Kit A B C A B 1 2 1 2 1...

Page 5: ...W 690 Flexio Extra Spray Kit A 20 30 cm B A C A B C D...

Page 6: ...W 690 Flexio Extra Spray Kit 1 2 3 4 2 1 1 1 3 2 1...

Page 7: ...W 690 Flexio Extra Spray Kit A B 1 2 3 4 5 6 7 4 5 3 1 2 7 8 3 4 5 6 4 4...

Page 8: ...W 690 Flexio Extra Spray Kit 1 2 3 4 5 6 7 SPARE PARTS...

Page 9: ...ount of Air Fig 14 10 14 Spray Technique 10 15 Taking Out of Operation and Cleaning 10 16 Cleaning the Wall Extra I Spray spray attachment 11 17 Cleaning the Gravity spray attachment 12 18 Maintenance...

Page 10: ...nts b Never use the tool in hazardous areas that contain flammable liquids gases or dusts Power tools generate sparks that can ignite the dust or vapors c Keep children and other persons away when usi...

Page 11: ...ch as dust mask non slip safety shoes safety helmet or ear protection depending on the type of power tools reduces the risk of injury c Avoid accidental starting up Make sure that the electric tool is...

Page 12: ...ired before using the tool Manyaccidentshavetheirorigininpowertoolsthathavebeenmaintainedbadly f Use the power tool accessories insert tools etc in accordance with these instructionsandinafashionspeci...

Page 13: ...vered by the explosion protection regulations To avoid the hazard of explosion when spraying provide for effective natural or artificial ventilation There must be no sources of ignition such as for ex...

Page 14: ...24 Practice poster 25 Operating instructions without illustration 26 Lubricating grease without illustration This is inside the container remove it before starting operations 5 Field of application Ma...

Page 15: ...ve tape manufacturer s instructions 7 Preparation of the Coating Material Mix the material well in the original container When using interior wall paint an agitator is recommended i W690hasbeendevelop...

Page 16: ...r once it is attached to the gun otherwise the coating material will leak out 10 Pour the prepared coating material into the container 11 Close the container with the cover 12 Attach the valve hoses t...

Page 17: ...ion Fig 11 A vertical flat jet for horizontal surfaces Fig 11 B horizontal flat jet for vertical surfaces Use the red adjustment lever to also switch between a wide and a narrow spray jet 11 Adjusting...

Page 18: ...not just from the wrist This ensures that a uniform distance is maintained between the spray gun and the spray surface during the spray operation Select a distance of 5 15 cm depending on the desired...

Page 19: ...er removal and lift it off 4 Unscrew the union nut fig 19 2 Clean the air cap 1 and nozzle 3 with a brush and solvent or water Attention Never remove the red nozzle seal from the nozzle If the nozzle...

Page 20: ...e seal is either damaged or missing If the nozzle seal is either missing or damaged liquids can enter the device and increase the risk of an electric shock 1 Push the nozzle seal fig 25 4 over the nee...

Page 21: ...tachment Remove the hose dismantle it and remove the membrane Fig 18 D Carefully clean all parts or replace if required During assembly insert the membrane fig 18 D with the pin pointing downwards 19...

Page 22: ...abouttheWAGNERrangeofproductsforrenovatingisavailable under www wagner group com 21 Environmental protection The device and all accessories and packaging have to be recycled in an environmentally frie...

Page 23: ...en container Refill Clean Clean Coating material drips from the nozzle Coating material assembly at air cap nozzle or needle Nozzle loose Nozzle seal worn Nozzle worn Clean Union nut tighten Change Ch...

Page 24: ...ical Data Technical Data Max viscosity Interior wall paint Varnish paints glazes etc 4000 mPas 60 DIN s Max flow rate Interior wall paint Varnish paints glazes etc 400 ml min 150 ml min Power source 2...

Page 25: ...or fitting or repair work which is not stated in our operating instructions Wearing parts are also excluded from the guarantee The guarantee excludes commercial use We expressly reserve the right to f...

Page 26: ...48882850 F 42 1313700077 PUT WAGNER SERVICE ul E Imieli 27 41 605 Swietochlowice T 48 32 346 37 00 F 48 32 346 37 13 D F DK S CH AUS H PL GB E SK P ORKLA HOUSE CARE AB Box 133 564 23 Bankeryd Sweden T...