Place the container seal (Fig. 29, 1) from
below on the suction tube (2) and slide it
over the collar, while turning the container
seal slightly.
•
Insert the suction tube (Fig. 29, 2) with
container seal in the gun body (3).
1
2
3
26. Correction of Malfunctions
Problem
Problem
Cause
Cause
Remedy
Remedy
No coating material
emerges from the
nozzle
•
Nozzle clogged
•
Material volume setting turned
too far to the left
•
Suction tube clogged
•
Suction tube loose
•
No pressure build-up in container
•
Ventilating bore (Fig. 25, 1)
clogged
•
Clean
•
Turn to the right
•
Clean
•
Insert
•
Tighten container
•
Clean
Coating material
drips from the
nozzle
•
Coating material assembly at air
cap, nozzle or needle
•
Nozzle loose
•
Nozzle seal is missing or worn
•
Nozzle worn
•
Clean
•
Tighten
•
Insert an intact nozzle
seal
•
Change