15
W 450 SE
GB
Viscosity, valve, round nozzle and multistep electronic system setting
data Multistep electronic system
Handling table
Fineadjustment knob:
For variable adjustment
Material
Viscosity
DINs
Valve:
Atomizer
colour
Round
nozzle:
Step electronic
system
Adjustment %
Resin primers
20 - 30
black
0,8*
50/25/12
Resin lacquers
20 - 30
black
0,8
50/25/12
Acrylic lacquers
20 - undiluted
black
0,8
50/25/12
Radiator paints,
Hammer finish paints
25 - 35
black
0,8
50/25/12
Timber impregnating
undiluted
black
0,8/1,2**
100
Aluminium paints
20 - 30
black
0,8
50/25/12
Underbody protection
(wax and bitumen base)
max. 80 - 100
black
1,2**
100
Plastic emulsions***
not measurable
approx. 10-20%
dilution
white
0,8
1,0**
100
Latex paints ***
not measurable
approx. 5 - 20%
dilution
white
0,8
1,0**
100
50/25/12
* Standard nozzle ** Part No. see accessory list page 18.
*** With paints, which contain fine quartz or other similar components, there is increased
wear of the valve and the nozzle. According to the scope of work, always have spare
parts available.
Measuring the Viscosity
Dip the viscosity test cup (Illus. 3) completely into the spray material. Hold the test cup up
and measure the time (in seconds) until the liquid empties out. Compare the measured
"runout time" with the Viscosity Table.
Valve data (handling table page 15)
The nozzle can be removed using the nozzle spanner. The valve is behind the nozzle
and comprises:
1. Atomizer head
2. Spring
3. Valve taper