5.3.4
VOLUME FLOW
Volume fl ow refers to water.
Maximum ranges for continuous operation at 50
/min.
5.3.5
PERFORMANCE DIAGRAMS
Stroke frequency
M
a
te
rial pr
essur
e in bar
Air c
onsumption nl/min
Water delivery rate l/min <gpm>
Wagner AL nozzles
Volume fl ow* in l/min
Spray angle
at
at
at
7 MPa
10 MPa
15 MPa
70 bar
100 bar
150 bar
inch
mm
1,015 psi
1,450 psi
2,175 psi
0.007
0.18
40°
0.1650
0.2000
0.2400
0.009
0.23
20-30-40-50-60°
0.2060
0.2500
0.3090
0.011
0.28
10-20-30-40-50-60°
0.2950
0.3450
0.4260
0.013
0.33
10-20-30-40-50-60-80°
0.4530
0.5280
0.6600
0.015
0.38
10-20-30-40-50-60-80°
0.5770
0.6720
0.8130
0.017
0.43
20-30-40-50-60-70°
0.7310
0.7860
1.0640
0.019
0.48
20-30-40-50-60-70-80°
0.9260
1.0920
1.3700
0.021
0.53
20-40-50-60-80°
1.1430
1.3600
1.6900
Wildcat 18-40
0.023
0.58
20-40-50-60-70-80°
1.3700
1.5900
2.0100
Puma 28-40
0.025
0.64
20-40-50-60-80°
1.6200
1.9100
2.4000
0.027
0.69
20-40-50-60-80°
1.8300
2.1300
2.6800
Wildcat 10-70
0.029
0.75
60°
2.1900
2.5100
3.1700
Puma 15-70
0.031
0.79
20-40-50-60°
2.4000
2.7700
3.4900
Leopard 35-70
0.025
0.90
20-40-50-60°
3.2200
3.7400
4.6900
Leopard 35-150, 48-110
0.043
1.10
20-50°
5.0700
6.0400
7.4600
Puma 15-150, 21-110
Jaguar 75-150
0.052
1.30
50°
5.1200
6.5000
7.5200
Example