32
B_03911
2
1
3
4
5
B_03913
1
3
2
B_03912
1
3
2
B_03703
4
OPERATING MANUAL
VERSION 01/2013
ORDER NUMBER DOC 2333538
Instead of the standard high-pressure fi lter the lower-cost
fi lter-relief combination and an inline fi lter can be used if
only a small volume of material will be processed.
Application: in pumps with a maximum material pressure
of 270 bar; 3916 psi.
You will fi nd the fi lter-relief combination and the suitable
inline fi lter in the accessories list.
1
Fluid section connection
2
Relief combination
3
Return line
4
Inline fi lter
5
Material outlet
5.4.3.2
RELIEF COMBINATION AND INLINE FILTER UP TO 270 BAR (OPTION)
5.4.4
STROKE COUNT (OPTION)
Each air motor has a 1/8" air connection with which the air pressure in the lower air motor
chamber can be measured. This signal can be used for counting the strokes in an external
control, for example.
The pressure signal corresponds to the set working air pressure and is available during the
complete upwards stroke of the pump. If both of the signal fl anks are evaluated, the upper
and lower reversal point can be determined. A 4/2mm; 0.16/0.08 inch air hose is used as
an air signal line.
Pneumatic pumps: Wildcat, Puma and Leopard
Pneumatic pumps: Jaguar
Order No. Designation
1
9998675
Threaded plug
2
9999066
Male stud elbow
3
9982072
Air hose (by length)
4
9943049
Pneumatic pre-selection counter