36
B_03916
OPERATING MANUAL
VERSION 01/2013
ORDER NUMBER DOC 2333538
Cable cross sections
Pump
4 mm2;
Paint container
6 mm2;
Conveyor
16 mm2;
Booth
16 mm2;
Spraying stand
16 mm2;
Procedure
1.
Screw on grounding cable with eye.
2.
Clamp the grounding cable clip to a grounding
connection on site.
3.
Earth the material (paint) container to a local
grounding connection.
4.
Ground the other parts of the system to a local
grounding connection.
16
mm2;