38
B_03918
B_03917
3
2
OPERATING MANUAL
VERSION 01/2013
ORDER NUMBER DOC 2333538
Before every start-up, the following points should be
observed as laid down in the operating manual:
- Secure gun with safety clip
- Check the permissible pressures.
- Check all connections for leaks.
- Check hoses for damage.
It should be ensured that the device is in the following
state before carrying out any work on it:
- The pressure should be released from the pump and
high-pressure hose with gun.
- The gun should be secured with safety clip.
- Interrupt the air supply.
Emergency Stop
In case of unforeseen occurrences the ball valve (2) should
be closed immediately and the return valve (3) opened.
6.5.2
FILLING UP WITH SEPARATING FLUID
Place the supplied separating fl uid into the separating fl uid cup.
Filling level:
1 cm; 0.4 inch under the cup edge.
Separating fl uid:
Order No. 9992504
Note
Maximum permissible inclination of pump for moving,
transportation etc. after fi lling it with separating fl uid ± 30°.
The pump must be vertical during operation.
Open
Closed
Open
Piston pump dry run!
High wear/damage to the packages.
Paint or solvent can escape if the seals are dry.
Ensure that the separating fl uid container is fi lled with suffi
cient separating fl uid.
Filling level 1 cm; 0.4 inch under the pot edge.
NOTICE