OPERATION
1.
Place empty container (5) under return pipe (4).
2.
Place suction hose (7) in the container with working material (6).
Note:
If the pump is equipped with a rigid suction system, it should only be dipped in into the working material
up to the middle of the inlet housing at the maximum!
3.
Adjust the pressure regulator (1) to approx. 0.05 MPa; 0.5 bar; 7.25.
4.
Open return valve (3).
5.
Slowly open the ball valve (2).
6.
Adjust the air pressure on the pressure regulator (1) so that the pump runs regularly.
7.
Close ball valve (2) as soon as pure working material starts coming from the return hose.
8.
Close return valve (3)
9.
Point the gun, without nozzle, into container (5) and open it.
10. Slowly open the ball valve (2).
11. Close ball valve (2) as soon as pure working material starts coming from the gun.
12. When there is no pressure remaining in the system close the gun.
13. Secure the gun.
14. Dispose of the contents of the container (5) according to the local regulations.
7.1
FILLING WITH WORKING MATERIAL
Closed
Open