42
OPERATING MANUAL
VERSION 01/2013
ORDER NUMBER DOC 2333538
7.2.3
DECOMMISSIONING AND CLEANING
7. Put the whole system back together.
8. Check the level of the separating fl uid -> Chapter 6.5.2.
9. Fill the system with fl ushing agent as laid down in Chapter 7.1 "Filling with Working
Material".
When storing the device for longer periods of time, it is necessary to thoroughly clean it
and protect it from corrosion. Replace the water or solvent in the material pump with a
suitable preservative, fi ll separating fl uid cup with separating fl uid.
Procedure
1. Carry out points 1 through 9 in Chapter 7.2.3 "Shutting Down and Cleaning".
2. Flushing with preservative according Chapter 6.5.3.
7.3
LONG-TERM STORAGE
Note
The device should be cleaned for maintenance purposes. Ensure that no remaining
material dries and sticks.
Procedure:
1.
Work interruptions -> carry out the steps in Chapter 7.2.2.
2.
Basic cleaning -> carry out the steps in Chapter 6.5.3.
3.
Maintain the gun as laid down in the operating manual.
4.
Clean and check the suction system and, in particular, the suction fi lter.
5.
When using a high pressure fi lter: clean and check fi lter insert and fi lter housing.
6.
Clean the outside of the system
Brittle fi lter pressure regulator!
The container on the fi lter pressure regulator becomes brittle
through contact with solvents and can burst.
Flying parts can cause injury.
Do not clean the container on the fi lter pressure regulator with
solvents.
WARNING
Gas mixtures can explode if there is an incompletely filled pump!
Danger to life from flying parts.
Ensure that the pump and suction system are always completely
filled with fl ushing agent or working medium.
Do not spray the device empty after cleaning.
WARNING