Operating manual Piston pump IceBreaker 40-200 ccm (Finishing)
6 Assembly and Commissioning
Order number 2333538 | Edition 03/2021
45
B_00304
7
6
5
1
2
3
4
8
Earthing schema (example)
Pos
Part / workstation
Cable cross section
1
Conveyor
16 mm²; AWG6
2
Work piece
--
3
R
max
< 1 M
Ω
--
4
Spraying stand
Alternative: Spray booth
16 mm²; AWG6
5
Floor, static dissipative
--
6
Product tank
6 mm²; AWG10
7
Pump
4 mm²; AWG12
8
Ex zone
--
Safe operation of the pump is only guaranteed with a grounding connection. Connect all
grounding cables using a short and direct route.
B_06960