8 Cleaning and Maintenance
52
Order number 2333538 | Edition 03/2021
8 CLEANING AND MAINTENANCE
8.1 CLEANING
8.1.1 Cleaning Personnel
Cleaning work should be undertaken regularly and carefully by qualified and trained
personnel. They should be informed of specific hazards during their training.
The following hazards may arise during cleaning work:
– risk to health from inhaling solvent vapors,
– use of unsuitable cleaning tools and aids.
8.1.2 Decommissioning and Cleaning
The device must be cleaned to change products and for maintenance purposes. Ensure that
no remaining product dries on and sticks to the device.
1. Interrupt the work sequence in accordance with Chapter Pressure Relief / Work
49].
2. Carry out basic flushing in accordance with Chapter Basic Flushing [
3. Empty system in a controlled manner according to Chapter Emptying Pump [
4. Service spray gun in accordance to its operating manual.
5. Clean and check the suction system and the suction filter.
6. Remove product filter (option): check and clean or replace filter insert and filter housing
in accordance with chapter Cleaning and Replacing the Filter [
7. Product change: If necessary, remove, clean and check the pump inlet housing. If
necessary, also remove, clean and check the fluid section.
8. Clean the outside of the system.
9. Fully assemble the system.
10. Check fill level of the separating agent in accordance with Chapter Filling with
54].
11. Fill the system with flushing agent in accordance with Chapter Filling the Empty Pump
57].
8.1.3 Storing for longer periods of time
If storing the system for a prolonged period of time, thorough cleaning and corrosion
protection are necessary. Replace the water or solvent in the product pump with a suitable
preserving agent and fill the separating agent tank with separating agent.
1. Carry out decommissioning and cleaning (steps 1 to 8) in accordance with Chapter
Decommissioning and Cleaning [
2. Fill the system with preservation agent in accordance with Chapter Filling the Empty
3. Empty the system in a controlled manner in accordance with Chapter Emptying Pump
56] and seal the openings.
8.2 MAINTENANCE
8.2.1 Maintenance Personnel
Maintenance work should be undertaken regularly and carefully by qualified and trained
personnel. They should be informed of specific hazards during their training.