Operating manual Piston pump IceBreaker 40-200 ccm (Finishing)
8 Cleaning and Maintenance
Order number 2333538 | Edition 03/2021
55
3. Additionally, the operator must regularly check the complete hoses for wear and tear as
well as for damage at intervals that he/she has set. Records of these checks must be
kept.
4. Replace the complete hose if one of the following two periods is exceeded:
4
6 years from the date of the hose crimping (see fitting embossing).
4
10 years from the date of the hose imprinting.
Fitting embossing
(if present)
Meaning
xxx bar
Pressure
yymm
Crimping date (year/month)
XX
Internal code
Hose imprinting
Meaning
WAGNER
Name / manufacturer
yymm
Date of manufacture (year/month)
xxx bar (xx MPa) e.g. 270 bar (27MPa)
Pressure
XX
Internal code
DNxx (e.g., DN10)
Nominal diameter