Operating manual Piston pump IceBreaker 40-200 ccm (Finishing)
8 Cleaning and Maintenance
Order number 2333538 | Edition 03/2021
57
5. As soon as working product is no longer flowing from the return tube (4), close the ball
valve (2).
6. Close return valve (3).
Emptying via the spray gun
1. Point the spray gun (3), without nozzle, into the tank (5) and pull the trigger.
2. Slowly open the ball valve (2). Be ready for the switch from working product to air.
3. As soon as no more working product is flowing, close the ball valve (2).
4. Close and secure the spray gun.
5. Carry out pressure relief in accordance with Chapter Pressure Relief / Work Interruption
49].
6. Dispose of the contents of the tank (5) according to the local regulations.
8.2.8 Filling the Empty Pump
WARNING
Gas mixtures can explode if there is an incompletely filled pump!
Danger to life from flying parts.
Ignition of potentially explosive surrounding atmosphere.
4
Empty and fill the device slowly and in a controlled manner.
4
Avoid potentially explosive atmosphere in the surroundings.
6
7
4
1
3
B_05292
5
2
A
B
A
Closed
B
Open
Before each filling, the nozzle must be removed from the spray gun. Here, the specifications
in the spray gun operating manual must be followed. In case of AirCoat systems, carry out
the filling of the system without atomizing air (8).